Review



fluid phase plasma complement bb  (Quidel)


Bioz Verified Symbol Quidel is a verified supplier
Bioz Manufacturer Symbol Quidel manufactures this product  
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 96

    Structured Review

    Quidel fluid phase plasma complement bb
    Fluid Phase Plasma Complement Bb, supplied by Quidel, used in various techniques. Bioz Stars score: 96/100, based on 184 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/human+complement+plasma/pm37093125-119-0-18
    Average 96 stars, based on 184 article reviews
    fluid phase plasma complement bb - by Bioz Stars, 2026-09
    96/100 stars

    Images

    Related Articles

    Clinical Proteomics:

    Article Title: Complement C3d/C4d Deposition on Platelets Correlates with 2'-O-Methoxyethyl Antisense Oligonucleotide-Induced Thrombocytopenia in Monkeys.
    Article Snippet: 2¢-O-Methoxyethyl antisense oligonucleotide (2¢-MOE ASO)-induced severe thrombocytopenia (TCP) [platelet (PLT) count <50 K/mL] was observed in the Asian-sourced cynomolgus monkeys with low incidence (2%–4% at doses >5 mg/kg/week).. The potential mechanisms for TCP were studied using the Mauritian-sourced cynomolgus monkeys, which were shown to be more susceptible to ASO-induced TCP, along with the Asiansourced animals.. ISIS 405879, a 2¢-MOE ASO, induced severe TCP (PLT <50 K/mL) in seven of nine Mauritian-sourced monkeys but not in the Asian-sourced monkeys after 16 weeks of treatment at 40 mg/kg/week.

    Article Title: The Local Complement Activation on Vascular Bed of Patients with Systemic Sclerosis: A Hypothesis-Generating Study
    Article Snippet: Serum and plasma samples were then aliquoted in 1.5 mL Eppendorf tubes and stored at -80°C until use. .. Concentrations of FH in serum and SC5b-9 in plasma were assessed using the Human Complement Factor H ELISA kit (Hycult Biotech, Uden, The Netherlands) and the MicroVue C5a Plus EIA (QUIDEL), respectively, according to the manufacturers’ instructions. ..

    Article Title: A randomized diet‐induced weight‐loss intervention reduces plasma complement C3 : Possible implication for endothelial dysfunction
    Article Snippet: .. Complement C3a was measured in EDTA plasma by ELISA (MicroVue C3a Plus EIA kit, Quidel Corp.) ( ). ..

    Article Title: A randomized diet-induced weight-loss intervention reduces plasma complement C3: Possible implication for endothelial dysfunction.
    Article Snippet: .. Complement C3a was measured in EDTA plasma by ELISA (MicroVue C3a Plus EIA kit, Quidel Corp.) (19). ..

    Enzyme-linked Immunosorbent Assay:

    Article Title: Complement C3d/C4d Deposition on Platelets Correlates with 2'-O-Methoxyethyl Antisense Oligonucleotide-Induced Thrombocytopenia in Monkeys.
    Article Snippet: 2¢-O-Methoxyethyl antisense oligonucleotide (2¢-MOE ASO)-induced severe thrombocytopenia (TCP) [platelet (PLT) count <50 K/mL] was observed in the Asian-sourced cynomolgus monkeys with low incidence (2%–4% at doses >5 mg/kg/week).. The potential mechanisms for TCP were studied using the Mauritian-sourced cynomolgus monkeys, which were shown to be more susceptible to ASO-induced TCP, along with the Asiansourced animals.. ISIS 405879, a 2¢-MOE ASO, induced severe TCP (PLT <50 K/mL) in seven of nine Mauritian-sourced monkeys but not in the Asian-sourced monkeys after 16 weeks of treatment at 40 mg/kg/week.

    Article Title: Novel and recurrent mutations in the C1NH gene of Arab patients affected with hereditary angioedema.
    Article Snippet: Background: Autosomal dominant hereditary angioedema (HAE) results in episodes of subcutaneous edema in any body part and/or submucosal edema of the upper respiratory or gastrointestinal tracts.. This disorder is caused by mutations in the C1NH gene, many of which have been described primarily in European patients.. However, the genetic cause of HAE in Middle Eastern Arab patients has not yet been determined.

    Article Title: The Local Complement Activation on Vascular Bed of Patients with Systemic Sclerosis: A Hypothesis-Generating Study
    Article Snippet: Serum and plasma samples were then aliquoted in 1.5 mL Eppendorf tubes and stored at -80°C until use. .. Concentrations of FH in serum and SC5b-9 in plasma were assessed using the Human Complement Factor H ELISA kit (Hycult Biotech, Uden, The Netherlands) and the MicroVue C5a Plus EIA (QUIDEL), respectively, according to the manufacturers’ instructions. ..

    Article Title: A randomized diet‐induced weight‐loss intervention reduces plasma complement C3 : Possible implication for endothelial dysfunction
    Article Snippet: .. Complement C3a was measured in EDTA plasma by ELISA (MicroVue C3a Plus EIA kit, Quidel Corp.) ( ). ..

    Article Title: A randomized diet-induced weight-loss intervention reduces plasma complement C3: Possible implication for endothelial dysfunction.
    Article Snippet: .. Complement C3a was measured in EDTA plasma by ELISA (MicroVue C3a Plus EIA kit, Quidel Corp.) (19). ..

    other:

    Article Title: Early Detection of Malignant Pleural Mesothelioma in Asbestos-Exposed Individuals with a Noninvasive Proteomics-Based Surveillance Tool
    Article Snippet: Complement Factor 9 (MicroVue SC5b-9 EIA kit, Quidel Corporation, San Diego, CA USA), Factor IX (AssayMax Human Factor IX ELISA kit, AssayPro St. Charles, MO USA) and Human CXCL13 (Human CXCL13/BLC/BCA-1 Quantikine ELISA kit, R&D Systems, Minneapolis, MN USA) were analyzed in order to validate SOMAmer results in the 68 controls and 32 MMs in the blinded validation trial.



    Similar Products

    93
    Innovative Research Inc human complement sera
    Optimization of the liposome composition to generate stealth liposomes. a Homogeneous <t>complement</t> assay of 10 mM SRB-encapsulating liposomes (10 µM total lipids; batches –6) showing the cholesterol dependency of liposome stealthiness in active serum (10 vol% PHS). Statistical analysis (two-sample independent t-test) revealed a significant difference between active and inactive serum samples at a cholesterol content of 10 mol% (p = 0.026) and above (p < 0.001). In contrast, no significant difference was observed at a cholesterol content of 5 mol% (p = 0.881). b Liposome stealthiness in active serum depending on SRB and cholesterol content (batches –10). 10 vol% human serum was used as a complement source (IRS41174). Statistical analysis (two-sample independent t-test) showed no significant difference between active and inactive serum samples of liposomes containing 10 mM SRB and 5 mol% cholesterol (p = 0.714), while in the other cases either a statistically significant amount of complement lysis (p < 0.001) or general serum stability was observed. Fluorescence measurements were carried out for 1 h at 37 °C in LCB, iaS, aS, and 30 mM OG + aS. Fluorescence intensities were normalized to the endpoint fluorescence of the positive control. λ Ex = 565(5 or 8) nm and λ Em = 585(5 or 8) nm; gain 150. T = 37 °C. n = 3. c Heterogeneous complement assay of biotin-modified chemiluminescence liposomes (30 mM m -carboxy luminol; batches CL1–2). Statistical analysis (two-sample independent t-test) showed a significant difference between active and inactive serum samples of high-cholesterol liposomes. Low-cholesterol liposomes remained stealth and showed no statistical difference in 5 and 10 vol% serum, whereas 25 vol% led to minor lysis in active serum. Liposomes (50 μM total lipids) were immobilized overnight on a streptavidin-coated MTP and incubated for 1 h at 37 °C in either inactive serum or active serum (5, 10, or 25 vol% PHS in LCB). Chemiluminescence measurements were performed by adding 50 μL of 4 μM hemin and 50 μL 40 mM H 2 O 2 in 0.01 M CBS, pH 10.5, 2 s integration time, gain 80, RH 1 mm, T = 25 °C, n = 3. d Flow chart of the homogeneous complement assay procedure for SRB-encapsulating liposomes
    Human Complement Sera, supplied by Innovative Research Inc, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/human+complement+plasma/Pooled+Human+Complement+Plasma/pmc12122657-67-1-14
    Average 93 stars, based on 1 article reviews
    human complement sera - by Bioz Stars, 2026-09
    93/100 stars
      Buy from Supplier

    91
    Assaypro plasma
    Optimization of the liposome composition to generate stealth liposomes. a Homogeneous <t>complement</t> assay of 10 mM SRB-encapsulating liposomes (10 µM total lipids; batches –6) showing the cholesterol dependency of liposome stealthiness in active serum (10 vol% PHS). Statistical analysis (two-sample independent t-test) revealed a significant difference between active and inactive serum samples at a cholesterol content of 10 mol% (p = 0.026) and above (p < 0.001). In contrast, no significant difference was observed at a cholesterol content of 5 mol% (p = 0.881). b Liposome stealthiness in active serum depending on SRB and cholesterol content (batches –10). 10 vol% human serum was used as a complement source (IRS41174). Statistical analysis (two-sample independent t-test) showed no significant difference between active and inactive serum samples of liposomes containing 10 mM SRB and 5 mol% cholesterol (p = 0.714), while in the other cases either a statistically significant amount of complement lysis (p < 0.001) or general serum stability was observed. Fluorescence measurements were carried out for 1 h at 37 °C in LCB, iaS, aS, and 30 mM OG + aS. Fluorescence intensities were normalized to the endpoint fluorescence of the positive control. λ Ex = 565(5 or 8) nm and λ Em = 585(5 or 8) nm; gain 150. T = 37 °C. n = 3. c Heterogeneous complement assay of biotin-modified chemiluminescence liposomes (30 mM m -carboxy luminol; batches CL1–2). Statistical analysis (two-sample independent t-test) showed a significant difference between active and inactive serum samples of high-cholesterol liposomes. Low-cholesterol liposomes remained stealth and showed no statistical difference in 5 and 10 vol% serum, whereas 25 vol% led to minor lysis in active serum. Liposomes (50 μM total lipids) were immobilized overnight on a streptavidin-coated MTP and incubated for 1 h at 37 °C in either inactive serum or active serum (5, 10, or 25 vol% PHS in LCB). Chemiluminescence measurements were performed by adding 50 μL of 4 μM hemin and 50 μL 40 mM H 2 O 2 in 0.01 M CBS, pH 10.5, 2 s integration time, gain 80, RH 1 mm, T = 25 °C, n = 3. d Flow chart of the homogeneous complement assay procedure for SRB-encapsulating liposomes
    Plasma, supplied by Assaypro, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/human+complement+plasma/Human+Complement+Factor+H+Deficient+Plasma/pm37191558-245-63-64
    Average 91 stars, based on 1 article reviews
    plasma - by Bioz Stars, 2026-09
    91/100 stars
      Buy from Supplier

    90
    Millipore human male ab plasma as a source of human complement
    Anti-KLRG1 monoclonal antibodies exert no apoptosis but induce ADCP, ADCC, and <t>complement-mediated</t> cytotoxicity (CDC). A, SMZ1-WT and SMZ1-KLRG1 cells were incubated with the indicated antibodies (mAb208, 13F12F2, or its isotype control mIgG2aκ) at increasing concentrations from 1 to 100 μg/mL or 0.2 or 1 μmol/L staurosporine (positive control) for 24 hours, and the percentage of apoptotic cells was quantified by flow cytometry. Three independent experiments were conducted. Shown are the mean values of technical triplicates with error bars representing SEM from one representative experiment. B–C, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human monocyte-derived macrophages (hMDM) from three healthy donors and bone-marrow–derived murine macrophages (mBMDM) from different lots of mice in the presence of indicated antibodies for 2 hours. Anti-CD47 mAb, MIAP410-mediated phagocytosis of Jurkat cells relative to its isotype control, mIgG1κ, was used as a positive control. The percentage of CFSE + macrophages (of human CD14 + or murine CD11b + cells) was determined by flow cytometry and plotted. D–E, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human-derived PBMCs from three healthy donors in the presence of indicated antibodies at increasing concentrations for 4 hours. The percentage of propidium iodide–positive (% PI pos; of CFSE + ) cells was determined by flow cytometry and plotted. Rituximab and Raji cells were used as a positive control. F–G, ADCC reporter assay measuring luminescence with murine FcγRIIIA-expressing Jurkat cells was performed in triplicate in three independent experiments at an effector:target ratio of 25:1 with indicated antibodies. Fold induction is relative to isotype control (mIgG2aκ for mAb208 and 13F12F2). Human anti-CD20 mAb and Raji cells were used as positive control along with its isotype control, hIgG1. Representative results from one experiment are shown. H–K, CDC assay with 30% murine and human complement was performed in triplicate in three independent experiments, and % PI pos cells were reported. Rituximab and Raji cells were used as positive controls. Shown are the mean values of technical triplicates, with error bars representing SEM from one representative experiment. *, P < 0.05; **, P < 0.01; ***, P < 0.001; ****, P < 0.0001 by two-sided Welch t test.
    Human Male Ab Plasma As A Source Of Human Complement, supplied by Millipore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/human+complement+plasma/human+plasma+complement+factor+h++cfh/pmc11145167-34-8-13
    Average 90 stars, based on 1 article reviews
    human male ab plasma as a source of human complement - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    90
    Millipore human plasma complement factor h (cfh
    Anti-KLRG1 monoclonal antibodies exert no apoptosis but induce ADCP, ADCC, and <t>complement-mediated</t> cytotoxicity (CDC). A, SMZ1-WT and SMZ1-KLRG1 cells were incubated with the indicated antibodies (mAb208, 13F12F2, or its isotype control mIgG2aκ) at increasing concentrations from 1 to 100 μg/mL or 0.2 or 1 μmol/L staurosporine (positive control) for 24 hours, and the percentage of apoptotic cells was quantified by flow cytometry. Three independent experiments were conducted. Shown are the mean values of technical triplicates with error bars representing SEM from one representative experiment. B–C, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human monocyte-derived macrophages (hMDM) from three healthy donors and bone-marrow–derived murine macrophages (mBMDM) from different lots of mice in the presence of indicated antibodies for 2 hours. Anti-CD47 mAb, MIAP410-mediated phagocytosis of Jurkat cells relative to its isotype control, mIgG1κ, was used as a positive control. The percentage of CFSE + macrophages (of human CD14 + or murine CD11b + cells) was determined by flow cytometry and plotted. D–E, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human-derived PBMCs from three healthy donors in the presence of indicated antibodies at increasing concentrations for 4 hours. The percentage of propidium iodide–positive (% PI pos; of CFSE + ) cells was determined by flow cytometry and plotted. Rituximab and Raji cells were used as a positive control. F–G, ADCC reporter assay measuring luminescence with murine FcγRIIIA-expressing Jurkat cells was performed in triplicate in three independent experiments at an effector:target ratio of 25:1 with indicated antibodies. Fold induction is relative to isotype control (mIgG2aκ for mAb208 and 13F12F2). Human anti-CD20 mAb and Raji cells were used as positive control along with its isotype control, hIgG1. Representative results from one experiment are shown. H–K, CDC assay with 30% murine and human complement was performed in triplicate in three independent experiments, and % PI pos cells were reported. Rituximab and Raji cells were used as positive controls. Shown are the mean values of technical triplicates, with error bars representing SEM from one representative experiment. *, P < 0.05; **, P < 0.01; ***, P < 0.001; ****, P < 0.0001 by two-sided Welch t test.
    Human Plasma Complement Factor H (Cfh, supplied by Millipore, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/human+complement+plasma/human+plasma+complement+factor+h++cfh/pmc10451625-76-18-25
    Average 90 stars, based on 1 article reviews
    human plasma complement factor h (cfh - by Bioz Stars, 2026-09
    90/100 stars
      Buy from Supplier

    91
    Assaypro iplasnac2ml
    Anti-KLRG1 monoclonal antibodies exert no apoptosis but induce ADCP, ADCC, and <t>complement-mediated</t> cytotoxicity (CDC). A, SMZ1-WT and SMZ1-KLRG1 cells were incubated with the indicated antibodies (mAb208, 13F12F2, or its isotype control mIgG2aκ) at increasing concentrations from 1 to 100 μg/mL or 0.2 or 1 μmol/L staurosporine (positive control) for 24 hours, and the percentage of apoptotic cells was quantified by flow cytometry. Three independent experiments were conducted. Shown are the mean values of technical triplicates with error bars representing SEM from one representative experiment. B–C, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human monocyte-derived macrophages (hMDM) from three healthy donors and bone-marrow–derived murine macrophages (mBMDM) from different lots of mice in the presence of indicated antibodies for 2 hours. Anti-CD47 mAb, MIAP410-mediated phagocytosis of Jurkat cells relative to its isotype control, mIgG1κ, was used as a positive control. The percentage of CFSE + macrophages (of human CD14 + or murine CD11b + cells) was determined by flow cytometry and plotted. D–E, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human-derived PBMCs from three healthy donors in the presence of indicated antibodies at increasing concentrations for 4 hours. The percentage of propidium iodide–positive (% PI pos; of CFSE + ) cells was determined by flow cytometry and plotted. Rituximab and Raji cells were used as a positive control. F–G, ADCC reporter assay measuring luminescence with murine FcγRIIIA-expressing Jurkat cells was performed in triplicate in three independent experiments at an effector:target ratio of 25:1 with indicated antibodies. Fold induction is relative to isotype control (mIgG2aκ for mAb208 and 13F12F2). Human anti-CD20 mAb and Raji cells were used as positive control along with its isotype control, hIgG1. Representative results from one experiment are shown. H–K, CDC assay with 30% murine and human complement was performed in triplicate in three independent experiments, and % PI pos cells were reported. Rituximab and Raji cells were used as positive controls. Shown are the mean values of technical triplicates, with error bars representing SEM from one representative experiment. *, P < 0.05; **, P < 0.01; ***, P < 0.001; ****, P < 0.0001 by two-sided Welch t test.
    Iplasnac2ml, supplied by Assaypro, used in various techniques. Bioz Stars score: 91/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/human+complement+plasma/Human+Complement+Factor+H+Deficient+Plasma/pm37191558-245-60-64
    Average 91 stars, based on 1 article reviews
    iplasnac2ml - by Bioz Stars, 2026-09
    91/100 stars
      Buy from Supplier

    96
    Quidel fluid phase plasma complement bb
    Anti-KLRG1 monoclonal antibodies exert no apoptosis but induce ADCP, ADCC, and <t>complement-mediated</t> cytotoxicity (CDC). A, SMZ1-WT and SMZ1-KLRG1 cells were incubated with the indicated antibodies (mAb208, 13F12F2, or its isotype control mIgG2aκ) at increasing concentrations from 1 to 100 μg/mL or 0.2 or 1 μmol/L staurosporine (positive control) for 24 hours, and the percentage of apoptotic cells was quantified by flow cytometry. Three independent experiments were conducted. Shown are the mean values of technical triplicates with error bars representing SEM from one representative experiment. B–C, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human monocyte-derived macrophages (hMDM) from three healthy donors and bone-marrow–derived murine macrophages (mBMDM) from different lots of mice in the presence of indicated antibodies for 2 hours. Anti-CD47 mAb, MIAP410-mediated phagocytosis of Jurkat cells relative to its isotype control, mIgG1κ, was used as a positive control. The percentage of CFSE + macrophages (of human CD14 + or murine CD11b + cells) was determined by flow cytometry and plotted. D–E, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human-derived PBMCs from three healthy donors in the presence of indicated antibodies at increasing concentrations for 4 hours. The percentage of propidium iodide–positive (% PI pos; of CFSE + ) cells was determined by flow cytometry and plotted. Rituximab and Raji cells were used as a positive control. F–G, ADCC reporter assay measuring luminescence with murine FcγRIIIA-expressing Jurkat cells was performed in triplicate in three independent experiments at an effector:target ratio of 25:1 with indicated antibodies. Fold induction is relative to isotype control (mIgG2aκ for mAb208 and 13F12F2). Human anti-CD20 mAb and Raji cells were used as positive control along with its isotype control, hIgG1. Representative results from one experiment are shown. H–K, CDC assay with 30% murine and human complement was performed in triplicate in three independent experiments, and % PI pos cells were reported. Rituximab and Raji cells were used as positive controls. Shown are the mean values of technical triplicates, with error bars representing SEM from one representative experiment. *, P < 0.05; **, P < 0.01; ***, P < 0.001; ****, P < 0.0001 by two-sided Welch t test.
    Fluid Phase Plasma Complement Bb, supplied by Quidel, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/human+complement+plasma/pm37093125-119-0-18
    Average 96 stars, based on 1 article reviews
    fluid phase plasma complement bb - by Bioz Stars, 2026-09
    96/100 stars
      Buy from Supplier

    Image Search Results


    Optimization of the liposome composition to generate stealth liposomes. a Homogeneous complement assay of 10 mM SRB-encapsulating liposomes (10 µM total lipids; batches –6) showing the cholesterol dependency of liposome stealthiness in active serum (10 vol% PHS). Statistical analysis (two-sample independent t-test) revealed a significant difference between active and inactive serum samples at a cholesterol content of 10 mol% (p = 0.026) and above (p < 0.001). In contrast, no significant difference was observed at a cholesterol content of 5 mol% (p = 0.881). b Liposome stealthiness in active serum depending on SRB and cholesterol content (batches –10). 10 vol% human serum was used as a complement source (IRS41174). Statistical analysis (two-sample independent t-test) showed no significant difference between active and inactive serum samples of liposomes containing 10 mM SRB and 5 mol% cholesterol (p = 0.714), while in the other cases either a statistically significant amount of complement lysis (p < 0.001) or general serum stability was observed. Fluorescence measurements were carried out for 1 h at 37 °C in LCB, iaS, aS, and 30 mM OG + aS. Fluorescence intensities were normalized to the endpoint fluorescence of the positive control. λ Ex = 565(5 or 8) nm and λ Em = 585(5 or 8) nm; gain 150. T = 37 °C. n = 3. c Heterogeneous complement assay of biotin-modified chemiluminescence liposomes (30 mM m -carboxy luminol; batches CL1–2). Statistical analysis (two-sample independent t-test) showed a significant difference between active and inactive serum samples of high-cholesterol liposomes. Low-cholesterol liposomes remained stealth and showed no statistical difference in 5 and 10 vol% serum, whereas 25 vol% led to minor lysis in active serum. Liposomes (50 μM total lipids) were immobilized overnight on a streptavidin-coated MTP and incubated for 1 h at 37 °C in either inactive serum or active serum (5, 10, or 25 vol% PHS in LCB). Chemiluminescence measurements were performed by adding 50 μL of 4 μM hemin and 50 μL 40 mM H 2 O 2 in 0.01 M CBS, pH 10.5, 2 s integration time, gain 80, RH 1 mm, T = 25 °C, n = 3. d Flow chart of the homogeneous complement assay procedure for SRB-encapsulating liposomes

    Journal: Analytical and Bioanalytical Chemistry

    Article Title: A homogeneous immunoassay technology based on liposomes and the complement system enables one-step, no-wash, rapid diagnostics directly in serum

    doi: 10.1007/s00216-025-05882-4

    Figure Lengend Snippet: Optimization of the liposome composition to generate stealth liposomes. a Homogeneous complement assay of 10 mM SRB-encapsulating liposomes (10 µM total lipids; batches –6) showing the cholesterol dependency of liposome stealthiness in active serum (10 vol% PHS). Statistical analysis (two-sample independent t-test) revealed a significant difference between active and inactive serum samples at a cholesterol content of 10 mol% (p = 0.026) and above (p < 0.001). In contrast, no significant difference was observed at a cholesterol content of 5 mol% (p = 0.881). b Liposome stealthiness in active serum depending on SRB and cholesterol content (batches –10). 10 vol% human serum was used as a complement source (IRS41174). Statistical analysis (two-sample independent t-test) showed no significant difference between active and inactive serum samples of liposomes containing 10 mM SRB and 5 mol% cholesterol (p = 0.714), while in the other cases either a statistically significant amount of complement lysis (p < 0.001) or general serum stability was observed. Fluorescence measurements were carried out for 1 h at 37 °C in LCB, iaS, aS, and 30 mM OG + aS. Fluorescence intensities were normalized to the endpoint fluorescence of the positive control. λ Ex = 565(5 or 8) nm and λ Em = 585(5 or 8) nm; gain 150. T = 37 °C. n = 3. c Heterogeneous complement assay of biotin-modified chemiluminescence liposomes (30 mM m -carboxy luminol; batches CL1–2). Statistical analysis (two-sample independent t-test) showed a significant difference between active and inactive serum samples of high-cholesterol liposomes. Low-cholesterol liposomes remained stealth and showed no statistical difference in 5 and 10 vol% serum, whereas 25 vol% led to minor lysis in active serum. Liposomes (50 μM total lipids) were immobilized overnight on a streptavidin-coated MTP and incubated for 1 h at 37 °C in either inactive serum or active serum (5, 10, or 25 vol% PHS in LCB). Chemiluminescence measurements were performed by adding 50 μL of 4 μM hemin and 50 μL 40 mM H 2 O 2 in 0.01 M CBS, pH 10.5, 2 s integration time, gain 80, RH 1 mm, T = 25 °C, n = 3. d Flow chart of the homogeneous complement assay procedure for SRB-encapsulating liposomes

    Article Snippet: Pooled human complement sera (batches 31,758, 33,478, 35,577, 41,174 and 45,270) were purchased from Innovative Research (Novi, MI, USA); ARMS peptide (peptide sequence: IHTELCLPAFFSPAGTQRRFQQPQHHLTLSIIHTAAR) was purchased from ProteoGenix (France).

    Techniques: Liposomes, Complement Assay, Lysis, Fluorescence, Positive Control, Modification, Incubation

    Homogeneous complement assay of 10 mM SRB-liposomes using antibodies as complement trigger. Time-resolved normalized fluorescence intensities of 0.5 mol% ARMS-modified liposomes (10 µM total lipids; batch ) a without or d with 0.5 mol% complement-triggering anti-ARMS antibody (A626). ARMS-liposomes were incubated with the A626 antibody for 1 h at 300 rpm. 10 vol% human serum was used as complement source (IRS35577). Time-resolved fluorescence intensities of biotinylated liposomes (1 µM total lipids; batch ) b without or e with 0.5 mol% complement-triggering anti-biotin antibody. Biotin-liposomes were incubated with the anti-biotin antibody for 1 h at 300 rpm. 5 vol% human serum was used as complement source (IRS45270). Time-resolved fluorescence intensities of PEGylated liposomes (1 µM total lipids; batch ) c without or f with 0.05 mol% complement-triggering anti-PEG antibody (clone RM105). PEG-liposomes were incubated with the anti-PEG antibody for 1 h at 300 rpm in 5 µL HSS. 5 vol% human serum was used as complement source (IRS45270). Fluorescence measurements were carried out for 1 h at 37 °C in LCB, iaS, aS and 30 mM OG + aS and normalized to the endpoint fluorescence of the positive control. λ Ex = 565(8) nm and λ Em = 585(8) nm; gain 150. T = 37 °C. n = 3

    Journal: Analytical and Bioanalytical Chemistry

    Article Title: A homogeneous immunoassay technology based on liposomes and the complement system enables one-step, no-wash, rapid diagnostics directly in serum

    doi: 10.1007/s00216-025-05882-4

    Figure Lengend Snippet: Homogeneous complement assay of 10 mM SRB-liposomes using antibodies as complement trigger. Time-resolved normalized fluorescence intensities of 0.5 mol% ARMS-modified liposomes (10 µM total lipids; batch ) a without or d with 0.5 mol% complement-triggering anti-ARMS antibody (A626). ARMS-liposomes were incubated with the A626 antibody for 1 h at 300 rpm. 10 vol% human serum was used as complement source (IRS35577). Time-resolved fluorescence intensities of biotinylated liposomes (1 µM total lipids; batch ) b without or e with 0.5 mol% complement-triggering anti-biotin antibody. Biotin-liposomes were incubated with the anti-biotin antibody for 1 h at 300 rpm. 5 vol% human serum was used as complement source (IRS45270). Time-resolved fluorescence intensities of PEGylated liposomes (1 µM total lipids; batch ) c without or f with 0.05 mol% complement-triggering anti-PEG antibody (clone RM105). PEG-liposomes were incubated with the anti-PEG antibody for 1 h at 300 rpm in 5 µL HSS. 5 vol% human serum was used as complement source (IRS45270). Fluorescence measurements were carried out for 1 h at 37 °C in LCB, iaS, aS and 30 mM OG + aS and normalized to the endpoint fluorescence of the positive control. λ Ex = 565(8) nm and λ Em = 585(8) nm; gain 150. T = 37 °C. n = 3

    Article Snippet: Pooled human complement sera (batches 31,758, 33,478, 35,577, 41,174 and 45,270) were purchased from Innovative Research (Novi, MI, USA); ARMS peptide (peptide sequence: IHTELCLPAFFSPAGTQRRFQQPQHHLTLSIIHTAAR) was purchased from ProteoGenix (France).

    Techniques: Complement Assay, Liposomes, Fluorescence, Modification, Incubation, Positive Control

    Dose–response curves of liposome lysis dependent on the antibody concentration. Corrected lysis values of a Biotin- (batch ) or b , c PEG-biotin-liposomes (batch ) (10 mM SRB, 1 µM total lipids) in a homogeneous complement assay performing an anti-biotin or anti-PEG (clone RM105 or clone 6.3) antibody titration. d Different combinations of these antibodies (0.03 mol% clone RM105, 0.1 mol% clone 6.3, 0.3 mol% anti-biotin antibody) with PEG biotin-liposomes (batch ). A one-way ANOVA, including a post hoc Tukey test, was performed for statistical analysis (p < 0.05) of the antibody combinations. Liposomes were incubated with the respective amount of antibodies for 1 h at 300 rpm. 5 vol% human serum was used as a complement source (IRS45270). Fluorescence intensities were adjusted by the iaS signal and normalized to the endpoint fluorescence of the positive control. λ Ex = 565(8) nm and λ Em = 585(8) nm; gain 150. T = 37 °C. n = 3

    Journal: Analytical and Bioanalytical Chemistry

    Article Title: A homogeneous immunoassay technology based on liposomes and the complement system enables one-step, no-wash, rapid diagnostics directly in serum

    doi: 10.1007/s00216-025-05882-4

    Figure Lengend Snippet: Dose–response curves of liposome lysis dependent on the antibody concentration. Corrected lysis values of a Biotin- (batch ) or b , c PEG-biotin-liposomes (batch ) (10 mM SRB, 1 µM total lipids) in a homogeneous complement assay performing an anti-biotin or anti-PEG (clone RM105 or clone 6.3) antibody titration. d Different combinations of these antibodies (0.03 mol% clone RM105, 0.1 mol% clone 6.3, 0.3 mol% anti-biotin antibody) with PEG biotin-liposomes (batch ). A one-way ANOVA, including a post hoc Tukey test, was performed for statistical analysis (p < 0.05) of the antibody combinations. Liposomes were incubated with the respective amount of antibodies for 1 h at 300 rpm. 5 vol% human serum was used as a complement source (IRS45270). Fluorescence intensities were adjusted by the iaS signal and normalized to the endpoint fluorescence of the positive control. λ Ex = 565(8) nm and λ Em = 585(8) nm; gain 150. T = 37 °C. n = 3

    Article Snippet: Pooled human complement sera (batches 31,758, 33,478, 35,577, 41,174 and 45,270) were purchased from Innovative Research (Novi, MI, USA); ARMS peptide (peptide sequence: IHTELCLPAFFSPAGTQRRFQQPQHHLTLSIIHTAAR) was purchased from ProteoGenix (France).

    Techniques: Lysis, Concentration Assay, Liposomes, Complement Assay, Titration, Incubation, Fluorescence, Positive Control

    Screening of anti-PEG antibodies in human sera. Corrected lysis values of PEGylated 10 mM SRB-liposomes (1 µM total lipids; batch ) in a homogeneous complement assay performing a serum titration of different commercial sera (IRS batches 31,758, 35,577, 41,174, and 45,270). 0.1–10 vol% of human sera were used. Fluorescence intensities were adjusted by the iaS signal and normalized to the endpoint fluorescence of the positive control. λ Ex = 565(8) nm and λ Em = 585(8) nm; gain 150. T = 37 °C. n = 3

    Journal: Analytical and Bioanalytical Chemistry

    Article Title: A homogeneous immunoassay technology based on liposomes and the complement system enables one-step, no-wash, rapid diagnostics directly in serum

    doi: 10.1007/s00216-025-05882-4

    Figure Lengend Snippet: Screening of anti-PEG antibodies in human sera. Corrected lysis values of PEGylated 10 mM SRB-liposomes (1 µM total lipids; batch ) in a homogeneous complement assay performing a serum titration of different commercial sera (IRS batches 31,758, 35,577, 41,174, and 45,270). 0.1–10 vol% of human sera were used. Fluorescence intensities were adjusted by the iaS signal and normalized to the endpoint fluorescence of the positive control. λ Ex = 565(8) nm and λ Em = 585(8) nm; gain 150. T = 37 °C. n = 3

    Article Snippet: Pooled human complement sera (batches 31,758, 33,478, 35,577, 41,174 and 45,270) were purchased from Innovative Research (Novi, MI, USA); ARMS peptide (peptide sequence: IHTELCLPAFFSPAGTQRRFQQPQHHLTLSIIHTAAR) was purchased from ProteoGenix (France).

    Techniques: Lysis, Liposomes, Complement Assay, Titration, Fluorescence, Positive Control

    Long-term storage stability study of 10 mM SRB-liposomes. Normalized fluorescence intensities of SRB-liposomes (10 µM total lipids) with different lipid compositions: a low-cholesterol, carboxylated (batch ); b low-cholesterol, PEGylated (batch ); and c high-cholesterol, biotinylated (batch ) in LCB, aS, or iaS throughout the long-term storage stability study up to 40 months at 4 °C. 10 vol% human serum was used as a complement source (PHS for 0–10 months and IRS45270 for the 40 months datapoint). Fluorescence intensities were normalized to the endpoint fluorescence of the positive control. λ Ex = 565(5) nm and λ Em = 585(5) nm; gain 150. T = 37 °C. n = 3. d Summary of the liposome storage stability at 4 °C, RT, and 37 °C

    Journal: Analytical and Bioanalytical Chemistry

    Article Title: A homogeneous immunoassay technology based on liposomes and the complement system enables one-step, no-wash, rapid diagnostics directly in serum

    doi: 10.1007/s00216-025-05882-4

    Figure Lengend Snippet: Long-term storage stability study of 10 mM SRB-liposomes. Normalized fluorescence intensities of SRB-liposomes (10 µM total lipids) with different lipid compositions: a low-cholesterol, carboxylated (batch ); b low-cholesterol, PEGylated (batch ); and c high-cholesterol, biotinylated (batch ) in LCB, aS, or iaS throughout the long-term storage stability study up to 40 months at 4 °C. 10 vol% human serum was used as a complement source (PHS for 0–10 months and IRS45270 for the 40 months datapoint). Fluorescence intensities were normalized to the endpoint fluorescence of the positive control. λ Ex = 565(5) nm and λ Em = 585(5) nm; gain 150. T = 37 °C. n = 3. d Summary of the liposome storage stability at 4 °C, RT, and 37 °C

    Article Snippet: Pooled human complement sera (batches 31,758, 33,478, 35,577, 41,174 and 45,270) were purchased from Innovative Research (Novi, MI, USA); ARMS peptide (peptide sequence: IHTELCLPAFFSPAGTQRRFQQPQHHLTLSIIHTAAR) was purchased from ProteoGenix (France).

    Techniques: Liposomes, Fluorescence, Positive Control

    Anti-KLRG1 monoclonal antibodies exert no apoptosis but induce ADCP, ADCC, and complement-mediated cytotoxicity (CDC). A, SMZ1-WT and SMZ1-KLRG1 cells were incubated with the indicated antibodies (mAb208, 13F12F2, or its isotype control mIgG2aκ) at increasing concentrations from 1 to 100 μg/mL or 0.2 or 1 μmol/L staurosporine (positive control) for 24 hours, and the percentage of apoptotic cells was quantified by flow cytometry. Three independent experiments were conducted. Shown are the mean values of technical triplicates with error bars representing SEM from one representative experiment. B–C, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human monocyte-derived macrophages (hMDM) from three healthy donors and bone-marrow–derived murine macrophages (mBMDM) from different lots of mice in the presence of indicated antibodies for 2 hours. Anti-CD47 mAb, MIAP410-mediated phagocytosis of Jurkat cells relative to its isotype control, mIgG1κ, was used as a positive control. The percentage of CFSE + macrophages (of human CD14 + or murine CD11b + cells) was determined by flow cytometry and plotted. D–E, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human-derived PBMCs from three healthy donors in the presence of indicated antibodies at increasing concentrations for 4 hours. The percentage of propidium iodide–positive (% PI pos; of CFSE + ) cells was determined by flow cytometry and plotted. Rituximab and Raji cells were used as a positive control. F–G, ADCC reporter assay measuring luminescence with murine FcγRIIIA-expressing Jurkat cells was performed in triplicate in three independent experiments at an effector:target ratio of 25:1 with indicated antibodies. Fold induction is relative to isotype control (mIgG2aκ for mAb208 and 13F12F2). Human anti-CD20 mAb and Raji cells were used as positive control along with its isotype control, hIgG1. Representative results from one experiment are shown. H–K, CDC assay with 30% murine and human complement was performed in triplicate in three independent experiments, and % PI pos cells were reported. Rituximab and Raji cells were used as positive controls. Shown are the mean values of technical triplicates, with error bars representing SEM from one representative experiment. *, P < 0.05; **, P < 0.01; ***, P < 0.001; ****, P < 0.0001 by two-sided Welch t test.

    Journal: Clinical Cancer Research

    Article Title: KLRG1 Cell Depletion as a Novel Therapeutic Strategy in Patients with Mature T-Cell Lymphoma Subtypes

    doi: 10.1158/1078-0432.CCR-23-3504

    Figure Lengend Snippet: Anti-KLRG1 monoclonal antibodies exert no apoptosis but induce ADCP, ADCC, and complement-mediated cytotoxicity (CDC). A, SMZ1-WT and SMZ1-KLRG1 cells were incubated with the indicated antibodies (mAb208, 13F12F2, or its isotype control mIgG2aκ) at increasing concentrations from 1 to 100 μg/mL or 0.2 or 1 μmol/L staurosporine (positive control) for 24 hours, and the percentage of apoptotic cells was quantified by flow cytometry. Three independent experiments were conducted. Shown are the mean values of technical triplicates with error bars representing SEM from one representative experiment. B–C, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human monocyte-derived macrophages (hMDM) from three healthy donors and bone-marrow–derived murine macrophages (mBMDM) from different lots of mice in the presence of indicated antibodies for 2 hours. Anti-CD47 mAb, MIAP410-mediated phagocytosis of Jurkat cells relative to its isotype control, mIgG1κ, was used as a positive control. The percentage of CFSE + macrophages (of human CD14 + or murine CD11b + cells) was determined by flow cytometry and plotted. D–E, CFSE-labeled SMZ1-WT and SMZ1-KLRG1 cells were incubated with human-derived PBMCs from three healthy donors in the presence of indicated antibodies at increasing concentrations for 4 hours. The percentage of propidium iodide–positive (% PI pos; of CFSE + ) cells was determined by flow cytometry and plotted. Rituximab and Raji cells were used as a positive control. F–G, ADCC reporter assay measuring luminescence with murine FcγRIIIA-expressing Jurkat cells was performed in triplicate in three independent experiments at an effector:target ratio of 25:1 with indicated antibodies. Fold induction is relative to isotype control (mIgG2aκ for mAb208 and 13F12F2). Human anti-CD20 mAb and Raji cells were used as positive control along with its isotype control, hIgG1. Representative results from one experiment are shown. H–K, CDC assay with 30% murine and human complement was performed in triplicate in three independent experiments, and % PI pos cells were reported. Rituximab and Raji cells were used as positive controls. Shown are the mean values of technical triplicates, with error bars representing SEM from one representative experiment. *, P < 0.05; **, P < 0.01; ***, P < 0.001; ****, P < 0.0001 by two-sided Welch t test.

    Article Snippet: Human male AB plasma as a source of human complement was obtained from Sigma-Aldrich.

    Techniques: Flow Cytometry Complement-Mediated Cytotoxicity Assay, Incubation, Positive Control, Flow Cytometry, Labeling, Derivative Assay, Reporter Assay, Expressing, CDC Assay